china power transformer manufacturer oil immersed transformer factory disconnector switch box type substation supplier
Menu
HV Disconnector Switch
Home » Products » HV Disconnector Switch » china Disconnector Switch factory GW4-110KV / GW4-40.5 Outdoor High Voltage Disconnector switch supplier
 china Disconnector Switch factory GW4-110KV / GW4-40.5 Outdoor High Voltage Disconnector switch supplier

china Disconnector Switch factory GW4-110KV / GW4-40.5 Outdoor High Voltage Disconnector switch supplier

GW4-110(D)(W) disconnector is a kind of HV outdoor electric equipments used in three-phase AC 50Hz electrical system. It is used for switching -on/off the HV circuit when there is no load in the circuit in order to change or transfer the circuit and also disconnect the current with the bus bar, breaker or any other HV electrical equipments when overhauling the circuitry.

Meaning of Type

Outdoor high voltage AC disconnector
high voltage AC disconnector

Introduction

The GW4-126(D)(W) disconnector is a kind of HV outdoor electric equipments used in three-phase AC 50Hz electrical system. It is used for switching -on/off the HV circuit when there is no load in the circuit in order to change or transfer the circuit and also disconnect the current with the bus bar, breaker or any other HV electrical equipments when overhauling the circuitry.

Thedisconnector is a double-post plane interrupter mid-opened type. It can match ground switch on 1 or 2 sides. It uses CS14G、CS17G or CS11 manual operating mechanism or CJ series electromotor operating mechanism to realize three-phase linking operation. The ground switch uses CS14G、 CS17G manual operating mechanism to realize three-phase linking operation.


Thedisconnector conforms to the standards of GB 1985-2004, DL/T486-200Xdisconnector=””ground=””switch=””>,GB/T 11022-1999, DL/T395 -2006which is constituted for the State Grid Corporation of China.

Working environment

1. Ambient temperature: -40°C – +60°C
2. Altitude: ≤ 3000m
3. Wind speed: ≤ 34m/s
4. Ice thickness:≤ 10mm
5. Earthquake intensity:≤ 8 degree
6. Air pollution level: III or 7. Sunlight radiate: 100W/m²(sunshine noon)

Technical data

ltem Unit Value
Rated voltage kV 40.5 72.5 126
Rated a)1 min power trequency withstand voltage(validvalue To earth kV 96 140 230
nsulating Interrupte kV 115 160 245
level b)Rated thunder impulse withstand voltage(peak) To earth kV 185 325 550
  Interrupter kV 215 375 630
Rated ftequoncy Hz 50
Rated current A 400  630  1000  1250  1600  2000  3150  4000
Rated short time withstand current kA 20  20  31.5  31.5  40  40  50  50
Ration peak withstand current 40  50  80  80  100  100  125  125
Rated short-circuit duration Main/earthing blade S  
Raled terminal mechanical load Honzontal portrait N 750 1000
Horizontal transvorse N 500 750
Vertical force N 750 1000
Creepage distance mm 1025-1250 1800-2250 3150-3900
Mechanical lite Times 2000
Manual operating mechanism Without earthing   CS11(CS17)
Single earthing   C88-6D(CS17)
Double eartng   Main blade CS14G(CS17);Earthing blade CS11(CS17)
Control loop voltage V AC220,DC110,DC220
Electromotor operating mechanism Type   CJ6
Motor yoltage V AC220,AC380,DC220
Control loop voltage V AC220,AC380,DC220
Switch-offlon time s 6±1
Weight of product Without earthing kg 360 500 700
Single earthing kg 410 600 800
Doutble earthing kg 460 700 900

 

Home ProductsAbout UsNewsServicesCERTIFICATEStechnical supportContact RSS
CoryRight © 2024 Lots Transformer Electric Co.Ltd-China power transformer oil immersed transformer disconnector switch box type substation manufacturer All Rights Reserved.